Skip to content

Human serum peptidase calibration audit

This audit addresses #543. It packages 12 study records and 27 reported hormone-stability measurements, with sources, assay conditions, perturbations, reuse terms and identifiability. The research result is a bounded evidence inventory and minimum calibration experiment. The audited inputs do not justify a new fit of transferable enzyme hazards for human long vaccine peptides and their fragments.

What was found

Evidence Available input What it identifies
Abid 2009, human serum oxidized NPY Km/Vmax, inhibitors, products Specific apparent DPP4/aminopeptidase-P/kallikrein reference rates; chemistry, pH 8 and manganese remain part of the assay
Kuoppala 2000, human plasma bradykinin Concentration-dependent product attribution ACE and CPN-like pathway dominance bounds, without transferable vaccine hazards
Yi 2015, matched human collection tubes Table 2: 27 half-life records; MS/antibody time-course figures; six TIF supplements Assay-specific peptide-signal stability and cocktail protection; individual enzyme contributions remain unresolved
Zhen 2016, human plasma FGF21 Selective FAP inhibitor, depletion and rescue; LC-MRM products and plotted trajectories Causal support for FAP's C-terminal cleavage of FGF21; a 181-aa protein and plotted endpoints do not calibrate vaccine peptide hazards
Bainbridge 2017, FAP probes Human-serum depletion, animal knockout and purified-enzyme comparisons FAP reporter specificity; ordinary GP probes are also cleaved by PREP. Selective D-Ala probes have dyes and noncanonical chemistry
Toräng 2016, human PYY In-vitro products and in-vivo sitagliptin arm Fragment and assay-endpoint differences; sampling inhibitors are quench reagents in vitro, and contaminated infusate prevents a reliable in-vivo conversion-rate estimate
Nyimanu 2019, human apelin In-vivo identified metabolites Products compatible with proposed MME activity; no matched MME perturbation to isolate its hazard
Dufresne 2017, broad human plasma peptidomics Supplemental peptide/protein matrix, precursor intensities and identification frequency Preanalytical proteolysis; ice/inhibitor versus warm samples confound temperature and inhibition, and products mix generation with loss
Yi 2007, human serum/plasma Broad inhibitor collection devices and endogenous fragments Sequential processing and anticoagulant effects; numerical trajectories/licensing were not established in this audit
FTMS 2007 Fractionated human peptide pool plus exogenous DPP4/APP2 Substrate discovery and a purified DPP4 kinetic validation; intact-matrix kinetics remain unmeasured
Maffioli 2020 Pig-plasma 228-peptide library and numerical products Broad boundary evidence, with no selective named-enzyme calibration or validated human transfer
Böttger 2017 Mouse blood/plasma/serum comparison Matrix/coagulation can alter mechanism and stability ranking; no human vaccine enzyme calibration

The machine-readable inventory records inspected downloads and hashes where available. API failures or unverified supplements stay explicit. A public supplement's existence is distinguished from successful local inspection. Searches covered human matrix degradation/inhibitors, DPP4/ACE/FAP/MME, matched peptidomics and MSP-MS libraries; this audit is not proof that no other dataset exists. Original figures and article prose are not redistributed.

Reproduce reported reference clocks

from mhctools import serum_calibration_evidence, serum_assay_parent_reference

records = serum_calibration_evidence()["measurements"]
reference = serum_assay_parent_reference("yi2015:t2:05", [0, 4, 8])

This record is GLP-1 G36A signal in human serum at room temperature, reported as 4 ± 0.2 hours. Under the source's first-order assumption its reference signal fractions are 1, 0.5 and 0.25. This is a reproduction of a reported parent clock, without fitting raw trajectories or assigning enzyme hazards. Amidation, matrix, assay and temperature remain explicit. Antibody-only and combined MS/antibody rows retain their observable/concentration ambiguity.

>96 h, <24 h and donor ranges remain bounds with no midpoint. A replicate SD is separate from those bounds and does not become a confidence interval. The 96-hour horizon is the study's maximum; individual row horizons were not reported in the table and stay unknown. No bond allocation, target-survival trajectory or vaccine sequence lookup is supplied by this reference. Original NPY enzyme-specific reference calculations remain in serum contributions.

Source inconsistencies are recorded: Table 2, methods and body report different room-temperature ranges; the glucagon EDTA range differs between table and body; OXM-K33 in methods differs from generic OXM table labels. Table 2 values are retained with these notes. Repeated assay/donor records are not independent training examples.

python scripts/serum_calibration_review.py --output /tmp/serum-calibration \
  --source-xml /path/to/PMC4519045.xml

This audits every Table 2 row, including rowspans, censoring and uncertainty, and exports source-linked JSON/CSV with checksums.

Minimum vaccine-specific calibration experiment

Use the actual peptide chemistry, selected epitope and observed target-bearing fragments. Compare vehicle with each selective inhibitor at the same temperature, substrate concentration, matrix fraction and donor preparation. Record serum/plasma processing, anticoagulant, pH, enzyme activation, inhibitor identity/dose/selectivity and sample IDs. Include orthogonal depletion/rescue and combination arms when needed to distinguish shared products and serial pathways.

Measure intact parent and identified target-bearing products over sufficiently dense early and late time points, using calibrated LC-MS, recovery controls, stable-isotope standards and LOD/LOQ. Multiple donors and concentrations are needed to assess donor variation and concentration dependence. Publish the numerical trajectories and source product identities.

Fit only identifiable competing/serial substrate-scoped rates. Hold out donors or sequences; separate parameter uncertainty from missing mechanisms. Report changes in exact-target availability on enzyme removal without renormalizing remaining hazards. MHC presentation and APC uptake need separate measurements.

For the shortest interpretation, use the three-route summary.